Power transformer basic specifications

Range from 3MVA to 150MVA up to 220kV class

1. Off load tap changer or selector

2. On load tap changer with drive mechanism and remote tap change control. In addition both automatic voltage regulation and parallel operation can be provided

3. Cooling specifications to ONAN, ONAF, KNAN, KNAF as required

4. Switchgear supplied and fitted on both HV and LV sides

In addition ancillary equipment such as oil temperature indicators, winding temperature indicators, pressure relief devises, neutral earthing equipment & current transformers for protection can be fitted.

Distribution transformers basic specifications

Range from 25kVA to 3000kVA up to 33kV class

1. Off load tap changer or selector

2. On load tap changer with drive mechanism and remote tap change control. In addition both automatic voltage regulation and parallel operation can be provided

3. Cooling specifications to ONAN, ONAF, KNAN, KNAF as required

4. Switchgear supplied and fitted on both HV and LV sides

In addition ancillary equipment such as oil temperature indicators, winding temperature indicators & pressure relief devises can be fitted.


List of Ancillary Products in our Portfolio

                       1* L.T.& H.T .Porcelain Insulators: LT shackle insulator, Guy/stay/strain
                                                                                  Insulators, Pin insulator, screw type
                                                                                  Insulator
                                                                                  H.T. 11/22/33KV Pin insulators,
                                                                                  11KV Disc insulators of 45/70/90
                                                                                  /120Kn ; 11KV Post insulators
                                                                                  Distribution Transformer Bushings
                                                                                  LT to 33KV


                        2* Neutral Grounding Earthing Resistors for Towers
                       

                         3* Conductors                                 : ACSR, AAC & AAAC
                                                                                   LT AB conductor
                        4* Hard-ware Fittings:                     :Suitable for Insulators
                                                                                   Suitable for Distribution and
                                                                                   Transmission lines.
                        5* Stay sets                                     : LT & HT ,Bow type or Screw
                                                                                   Type as your requirement
                        6* Earthing Rods                            : Copper coated

                        7*Cables                                          : LT and HT control and Power cables
                                                                                   PVC insulated, armoured/unarmored
                                                                                   LT & HT XLPE cables

                        8* Transformers                              :Isolation transformers, Auto
                                                                                  Transformers and Reactors(Chokes)
                                                                                  Control transformers 100VA to 100
                                                                                  KVA  air cooled Single Phase&
                                                                                  Three Phase

                                                                                  Oil filled Distribution Transformers
                                                                                  15KVA to 2000KVA suitable for
                                                                                  Sub-station, Pole mounting, etc.
                                                                                  Oil Filled Power Transformers:
                                                                                  5MVA to 250MVA for 33KVto 220
                                                                                  KV

                        9* Capacitors                                   : Oil filled LT & HT capacitors

                        10* G.I. Wire                                    : Stay wires, Earth wire, Barbed
                                                                                     wire
                                                                                   


                       11*Lightning Arrestors                    : Suitable for 11KV to 400Kv

                       12* Outdoor Disconnecting             :  A.B.Switches, D.O. Fuses,
                             switches                                          H.G Fuse Units
                                                                                   Isolators 33KV to 400KV

                       13*C.T.and P.T.                             : L.T. ring type, window type
                                                                                   PVC insulated or Epoxy cast
                                                                                   H.T. Oil filled 11KV to 220KV

                       14*Ring Main Unit                         : 11KV 22KV Oil Filled or Gas
                                                                                  Filled RMU

                       15* Testing Equipments                 : Oil Breakdown tester,
                                                                                 Insulation Resistance (IR) Tester
                                                                                 Capacitance Meter
                                                                                 Transformer Voltage Ratio Meter
                                                                                 Capacitance Tan-delta measurement
                                                                                 System
                                                                                 Surge comparison Tester
                                                                                 Transformer winding resistance Meter

                      16* Oil Filteration Plants                : 300LPH to 20000LPH

                      17*  Transformer Oil                      : For all Oil Filled Transformers

                      18* Circuit Breakers                      : ABB/Siemens/CG makes for various power ratings